Аddress: 3808 Zhencheng Road , Jiangyin city, Jiangsu Province, China
Zip code: 214400
Introduction
CHP-80 may be used for various polymerization reactions. It can be used in emulsion, solution and bulk polymerizations. In emulsion processes, CHP-80 may be activated by organic-soluble or water-soluble reducing agents, or by metal compounds to achieve polymerization at room temperature or lower. When no accelerators are used, effective polymerization can be obtained in the temperature range of 50-200°C. For example, styrene and methyl methacrylate can be polymerized in bulk in the temperature range of 60-100°C using CHP- 80. CHP-80 may also be used for emulsion polymerization of various vinyl monomers. In this case CHP-90 may be used in combination with reducing agents to achieve reproducible results at low temperatures.
Specifications
Active oxygen
8.40-8.94 %
Appearance
Clear liquid
Assay
80.0-85.0 %
Color
≤ 200 Pt-Co
Specifications
Active oxygen
8.40-8.94 %
Appearance
Clear liquid
Assay
80.0-85.0 %
Color
≤ 200 Pt-Co
Characteristics
Density, 20 °C
0.900 g/cm³
Viscosity, 20 °C
35 mPa.s
Applications
CHP-80 can be used for the market segments: polymer production, thermoset composites and acrylics production with their different applications/functions. For more information please check our website and/or contact us.
Half-life data
The reactivity of an organic peroxide is usually given by its half-life (t1/2) at various temperatures. The half-life of CHP-80 in chlorobenzene is:
0.1 hr
at 195°C
1 hr
at 166°C
10 hr
at 140°C
Formula 1
kd=A·e-Ea/RT
Formula 2
t½ = (ln2)/kd
Ea
132.56 kJ/mole
A
1.15E+12 s-1
R
8.3142 J/mole·K
T
(273.15+°C) K
Thermal stability
Organic peroxides are thermally unstable substances, which may undergo self-accelerating decomposition. The lowest temperature at which self-accelerating decomposition of a substance in the original packaging may occur is the Self- Accelerating Decomposition Temperature (SADT). The SADT is determined on the basis of the Heat Accumulation Storage Test.
SADT
75°C for small cans, 70°Cfor IBC’s and 65°C for bulk tanks.
Method
The Heat Accumulation Storage Test is a recognized test method for the determination of the SADT of organic peroxides (see Recommendations on the Transport of Dangerous Goods, Manual of Tests and Criteria – United Nations, New York and Geneva).
Storage
Due to the relatively unstable nature of organic peroxides a loss of quality can be detected over a period of time. To minimize the loss of quality, Thousands Chemicals recommends a maximum storage temperature (Ts max.) for each organic peroxide product.
Ts max.
40°C
Ts min.
-30°C *
Note
* to prevent crystallization. When stored under these recommended storage
conditions, CHP-80 will remain within the Thousands Chemicals pecifications for a period of at least 6 months after delivery.
Packaging and transport
CHP-80 is packed in a 30 liter HDPE can for 25 kg peroxide and 200 kg HDPE drums of 180 kg net weight. Both packaging and transport meet the international regulations. For the availability of other packed quantities contact your Thousands Chemicals representative. CHP-80 is classified as Organic peroxide type F; liquid, Division 5.2; UN
3109.
Safety and handling
Keep containers tightly closed. Store and handle CHP-80 in a dry well-ventilated place away from sources of heat or ignition and direct sunlight. Never weigh out in the storage room. Avoid contact with reducing agents (e.g. amines), acids, alkalis and heavy metal compounds (e.g. accelerators, driers and metal soaps). Please refer to the Safety Data Sheet (SDS) for further information on the safe storage, use and handling of CHP-80. This information should be thoroughly reviewed prior to acceptance of this product.